日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

キャリブレーションarXiv:2611.31054

マニピュレータキャリブレーションにおけるDH・Hayati・CPC・POEモデル間の解析的変換スキームの完成

Completing analytical conversion scheme among DH, Hayati, CPC and POE models for manipulator calibration

シェア:XThreadsFacebookLINEはてブBluesky

ロボットの運動学モデル(DH, Hayati, CPC, POE)間で未確立だったPOE-HAYとHAY-CPCの直接解析変換をリー群理論に基づき導出し、キャリブレーション精度向上への有用性を示した論文。

著者: Oleg Yu. Sumenkov, Danil D. Kulminskiy, Sergei V. Gusev

分類: cs.RO

原文アブストラクト

Building on Mooring's decomposition of the calibration procedure into four stages - modeling, measurement, identification, and correction - this paper investigates the role of analytical kinematic model conversion algorithms within the calibration framework and their potential to improve calibration performance. Four prominent and widely cited kinematic models: Denavit-Hartenberg (DH), Hayati (HAY), Complete and Parametrically Continuous (CPC), and Product of Exponentials (POE), - are considered. A systematic analysis of the existing conversion relationships reveals that, although most conversions among these models have already been established in the literature, a direct analytical conversion between POE and HAY, and CPC and HAY remains unavailable. Relying instead on a sequential combination of the existing POE-DH and DH-HAY conversions, for example, introduces several limitations. To address this gap, we develop a constructive analytical conversion between POE-HAY and HAY-CPC models based on Lie group theory, formally established through a set of lemmas and propositions. The proposed algorithms are illustrated using an RRRP SCARA robot and an RRHHHH Puma 560 manipulator. The direct POE-HAY conversion is compared with the sequential POE-DH-HAY approach, as well as HAY-CPC in terms of several relevant criteria, demonstrating the advantages of the proposed solution. Finally, we demonstrate the practical significance of the completed analytical conversion framework in an open-loop kinematic calibration experiment on an ABB IRB 1600 manipulator, using an API Radian EMSD3 Laser Tracker for measurements. The experimental results demonstrate that proper model selection combined with completed analytical conversion scheme directly improves calibration accuracy.

関連論文

  1. 1X Square Robot、VLA基盤モデル「WALL-OSS-1.0」を発表 実機312タスクで成功率55.1%新製品・発表
  2. 2NVIDIA、RTX Spark小型デスクトップを発売 ASUS、Dell、MSIから半導体・GPU
  3. 3Boston Dynamics、GlobalFoundriesでAtlasを試験へ 半導体製造で2027年初頭から半導体・GPU
  4. 4X Square RobotとPos Malaysia、物流自動化で協業覚書提携・買収
  5. 5丸文、RealManのロボットアームやヒューマノイドを国内販売提携・買収

PR・アフィリエイト広告

OZ GAMING(GPU搭載BTOゲーミングPC)

OZ GAMING(GPU搭載BTOゲーミングPC)の公式広告バナーOZ GAMINGで完成品PCを見る ↗
PR本紙発行元 EmplifAI